PLC Data to Cloud in Qatar
Read run states, counts and process values from the Siemens, Rockwell and other PLCs you already run, over OPC UA, EtherNet/IP or Modbus TCP, without touching the control logic.
Last updated
What does PLC data to cloud mean?
Getting PLC data to the cloud means reading values a controller already holds, such as run state, counts, speeds and temperatures, and sending them to a platform outside the control network. An edge gateway reads each PLC over OPC UA or its native protocol, read-only, and forwards the values, so production and maintenance teams see them live.
Each PLC already knows whether its machine is running, how many units it made and how hot the glue tank is. The question is how to get those values out without risking the line: a read-only connection through a gateway in its own network zone, with your automation team agreeing every tag.
This is the layer under OEE monitoring and downtime tracking: once the tags are mapped, both run on the same feed.
SCADA exports
The data sits on one site's server and leaves by spreadsheet.
Changing the PLC program
New logic to push data out, with a stop and retesting.
Read-only edge gateway
Reads the tags the PLC already exposes. The program stays as it is.
Four protocols, and what each one needs.
How the gateway talks to a PLC depends on its make and age.
| Protocol | Common on | What to check first |
|---|---|---|
| OPC UAVendor-neutral | Siemens S7-1200 and S7-1500, many other modern PLCs, SCADA and OPC servers | Server switched on; on Siemens CPUs, an OPC UA runtime licence per CPU; a user with read-only rights |
| Siemens S7ISO-on-TCP, port 102 | Siemens S7 PLCs, S7-1200 and S7-1500 included | On S7-1200 and S7-1500, PUT/GET access and non-optimised data blocks; PUT/GET also allows remote writes |
| EtherNet/IPCIP, TCP port 44818 | Rockwell Allen-Bradley ControlLogix, CompactLogix and Micro800 | Controller tag names; explicit messaging runs over TCP |
| Modbus TCPPort 502 | Older PLCs, drives and meters | A register map from the machine builder, since Modbus registers carry numbers only |
Sources: OPC UA, OPC Foundation; licence per CPU, Siemens Industry Mall (S7-1200) and OSD Schenck (S7-1500); S7, Coreflux and Industrial Monitor Direct; EtherNet/IP, Wikipedia and Software Toolbox; Modbus TCP, Nanotec. Older and proprietary protocols are reached through middleware such as Kepware or Ignition, so any controller either of them supports can be connected.
Network segregation, by zones and conduits.
IEC 62443 groups plant assets into zones with the same security needs, joined by conduits that control what crosses between them.
| Element | In IEC 62443 terms | In a Quoriam connection |
|---|---|---|
| Control zone | PLCs, HMIs and SCADA that run the process | Unchanged. The gateway reads from it through a conduit you control |
| Conduit to the PLCs | A defined path between zones, enforced by firewall rules as specific as possible | Named PLCs, named ports, requests from the gateway only |
| Gateway zone | A separate zone between the control network and the business network | The edge gateway sits here |
| Conduit to the platform | The path out to the business network or the internet | Outbound from the gateway to the Quoriam platform |
| Security level | A target level for each zone and conduit, set from a risk assessment | Set by your OT security team; the gateway is configured to it |
Zones, conduits and security levels: INCIBE-CERT and Automation.com.
How it works.
Survey
With your automation team, we list each PLC's make, model, firmware and protocol, and agree the tags to read.
Connect
The Quoriam Edge QE35 connects through the conduit your OT team approves and reads each PLC over OPC UA or its native protocol, read-only.
Map
Each tag gets a name, a unit and a machine, so LB-204's glue temperature reads as that everywhere.
Watch the link
Uplink, sync times and errors are monitored, with an alert if a PLC stops answering.

System view
For IT, OT and security reviewers: where the data goes, and how.
- On the linePLCs, SCADA or an existing OPC server
- At the edgeQuoriam Edge QE35 in its own network zone, read-only
- NetworkPlant network or cellular, encrypted and kept apart from the control network
- Quoriam platformOn your premises or cloud hosted in Qatar
- Your team and systemsOEE, downtime and maintenance on Quoriam; data to your ERP
Hardware and integrations.
One gateway per line or hall, reading what is already there.
- Edge gatewayQuoriam Edge QE35, on the plant network or its own zone

- Existing OPC serversSCADA or a plant OPC UA server, read instead of each PLC
- State and count sensorsOnly on machines without a PLC

- Reads from
- PLCs over OPC UA, Modbus TCP and EtherNet/IP; SCADA over OPC UA
- Writes to
- Nothing on the control network
- Sends to
- The Quoriam platform; ERP systems
Hardware agnostic. Makes we fit includeMilesightFootfallCamTeltonikaAdvantechWe can work with any maker and choose the device for each site. The platform reads them all.
What your team sees.
What is connected, and what the tags turn into.



Where it's used in Qatar.
Anywhere useful data is locked in a controller.
Production lines
Food, packaging and building-materials lines in Mesaieed and the free zones.
ManufacturingPump stations and utilities
PLCs at unmanned stations, read for run status, pressure and flow.
Remote operations monitoringOil, gas and energy
Package PLCs on compressors and skids, read without changing the vendor's program.
Oil, gas and energy
Questions buyers ask.
Something else? Ask us during the free assessment.
How do you get PLC data to the cloud?
An edge gateway on the plant network reads tag values from each PLC, over OPC UA or the PLC's own protocol, and sends them to the Quoriam platform. The PLC program is not changed. Your automation team approves the tags and the network path.
Is it safe to connect a PLC to the cloud?
With the right design, yes. IEC 62443 separates the control network into zones joined by controlled conduits; the gateway sits in its own zone, reads PLCs read-only and connects outward to the platform. Your OT security team sets the target security level and the firewall rules.
What is OPC UA?
OPC UA is a vendor-neutral standard for exchanging industrial data, released by the OPC Foundation in 2008. It runs on anything from a PLC to a cloud server, and supports certificate authentication, signed and encrypted messages and audit logs. Many modern PLCs have an OPC UA server built in, sometimes behind a licence.
Which PLCs and protocols do you support?
Siemens, Rockwell, Schneider, ABB, Mitsubishi and Omron controllers, among others, over OPC UA, Modbus TCP or EtherNet/IP, and SCADA over OPC UA. Older PLCs and proprietary protocols are reached through middleware such as Kepware or Ignition, so anything either of them supports can be connected, and the list keeps growing. Send us the make, model and firmware of each PLC and we confirm the route.
Do we need to change the PLC program?
No logic changes. Some PLCs need a setting changed first: switching on the OPC UA server, adding its licence, or on Siemens S7-1200 and S7-1500, allowing PUT/GET access. Each means a download to the PLC at a planned stop. We prefer OPC UA, since PUT/GET also opens remote writes.
What hardware is needed?
One Quoriam Edge QE35 gateway usually serves a line or a hall, on the plant network or a separate zone. Machines with no PLC get a state or count sensor. Where you already run SCADA or an OPC server, we can often read that instead of each PLC.
What does a PLC connection cost?
It depends on how many PLCs you connect, their protocols and the network work needed. Most plants start with one line as a pilot. The free three-week assessment surveys your PLCs and network, then gives a scope and a fixed price.
Related.
PLC data connectivity is part of factory intelligence on the Quoriam platform.
- Factory intelligence
Live line status, OEE and downtime reasons from the PLCs you already run.
- OEE monitoring
Availability, performance and quality per line and shift, from the PLC.
- Downtime tracking
Every stop logged with its reason, so the biggest losses get fixed first.
- Remote operations monitoring
Valves, tanks, pumps and solar arrays across remote sites on one screen, with alarms on any change.
Get the data out without touching the line.
A free three-week assessment. We survey your PLCs, protocols and network with your automation team, then recommend the safest route for each machine.
We take on two assessments a month.Quoriam is designed to pay back within six months. How we calculate payback